G1602 is universal indicator, based on microcontrollers. It is intended for use in all areas, where weight measurement is necessary. The client can change all metrological aspects of the scale and to use additional functions (counting, percent indication, blocking, PC connection, etc.). Also special modes of work are implemented to prevent unauthorized measurement or malicious acts (like stealing). G1602 comes in industrial box with class of protection IP54, but when ordered it can be protected up to IP67. Large weight display and ergonomic keyboard allow easy work and use. Additionally two smaller LED displays are provided, which are used in non-weight functions. Applies the requirements of EN 45501:2001 (OIML R76-1 and 2).

user manual


G1602 has the following parameters and functions:

number of divisions 500 - 30 000, step 500
division value 1,2,5*10ˆк g., К = -1 ÷ 6
decimal point position 1..4
button ZERO range, in percents 0 ÷ 20%
zero tracking speed (0,0е ÷ 0,9е)/1s
button TARE range, in percents 10 ÷ 100%
maximal display value Мах + (0е ÷ 100е)
hanging tracking speed (0,0е ÷ 1,9е)/20s
counting function On/Off
percent function On/Off
control of up to two relay outputs On/Off
work with predefined articles On/Off
work with direct price calculation On/Off
work with labeling printer On/Off
work with blocking mode after equilibrium On/Off
manual TARE On/Off
altitude correction 0 - 2000m
latitude correction

Main technical parameters of G1602

weight measurement, using tensometric load cells
input resistance (signal) > 1 MOhm
output resistance of sensor 82 Ohm ÷ 2 kOhm
sensor connection type 4/6-wire
sensitivity 0.5uV
maximal range of measuring signal 30mV
maximal cable lengths, when 4-wire connection is used 5m; cable type LIYCY 4x0.5mm2
display triple super bright red - 5-digit weight display, digit height 20.0mm, 2х6-digit additional displays, digit height 10mm
keyboard 16-button keyboard
serial interface RS-232 standard; RS-485 option
measurement cycle < 1 s
measurement error 0,5е; for class III - according to EN 45501:2001
power consumption < 2 W
work temperature from -10° C to +40° C
storage temperature from -50° C to +90° C
dimensions (H/W/D) 160/175/80 mm
mounting on horizontal or vertical surface
power supply 220V (+10% / -15%), 50Hz; 12V DC option
protection class IP54 standard, higher is an option
own weight 1.1 kg

Additional information